HEA Table — Dimensions, Weight & Section Properties

HEA wide-flange beam per EN 10365 (DIN 1025-3)

Standard values for every HEA size from HEA 100 to HEA 600: dimensions, weight per meter, and the section properties needed for bending and deflection checks. Click a size for its full data sheet.

HEA — HEA 100 – HEA 600

Profileh (mm)b (mm)tw (mm)tf (mm)G (kg/m)A (cm²)Ix (cm⁴)Wx (cm³)Iy (cm⁴)Wy (cm³)
HEA 100961005816.721.234972.813426.8
HEA 1201141205819.925.360610623138.5
HEA 1401331405.58.524.731.41,03315538955.6
HEA 1601521606930.438.81,67322061676.9
HEA 18017118069.535.545.32,510294925103
HEA 2001902006.51042.353.83,6923891,336134
HEA 22021022071150.564.35,4105151,955178
HEA 2402302407.51260.376.87,7636752,769231
HEA 2602502607.512.568.286.810,4508363,668282
HEA 28027028081376.497.313,6701,0134,763340
HEA 3002903008.51488.311218,2601,2606,310421
HEA 320310300915.597.612422,9301,4796,985466
HEA 3403303009.516.510513327,6901,6787,436496
HEA 3603503001017.511214333,0901,8917,887526
HEA 400390300111912515945,0702,3118,564571
HEA 45044030011.52114017863,7202,8969,465631
HEA 500490300122315519886,9703,55010,370691
HEA 55054030012.524166212111,9004,14610,820721
HEA 6005903001325178226141,2004,78711,270751

HEA load capacity — max. uniform load (kN/m), simply supported

Profile3 m4 m5 m6 m8 m
HEA 1005.792.441.250.720.31
HEA 12010.14.242.171.260.53
HEA 14017.17.233.72.140.9
HEA 16027.811.763.471.46
HEA 18040.517.695.212.2
HEA 20053.625.813.27.663.23
HEA 2207137.919.411.24.73
HEA 2409352.327.816.16.79
HEA 26011564.837.521.79.14
HEA 28014078.54928.412
HEA 30017497.762.537.916
HEA 32020411573.447.620.1
HEA 34023113083.257.424.2
HEA 36026114793.865.129
HEA 40031817911579.639.4
HEA 45039922414499.855.8
HEA 50048927517612268.8
HEA 55057132120614380.3
HEA 60066037123716592.7

Frequently Asked Questions

What is an HEA profile?

HEA is a standard European hot-rolled beam series per EN 10365 (DIN 1025-3). Sizes run from HEA 100 (16.7 kg/m) to HEA 600 (178 kg/m).

How do I read the HEA table?

h and b are the section height and flange width in mm, G is the weight per meter, A the cross-section area, Ix/Wx the moment of inertia and section modulus about the strong axis, and Iy/Wy the same about the weak axis. Click any size for the full data sheet with a worked deflection example.

How much load can an HEA beam carry?

The load capacity table above gives the maximum uniformly distributed load per span for a simply supported beam — the stricter of the L/360 deflection limit (E = 210 GPa) and an elastic bending stress of 155 MPa (≈ 0.66·fy for S235). Example: HEA 280 carries about 78.5 kN/m over a 4 m span. Preliminary sizing only — verify the final design to Eurocode 3, including shear, bearing, and lateral-torsional buckling.

What is the difference between IPE, HEA and HEB?

IPE beams are narrow and light — the default for bending about the strong axis. HEA and HEB are wide-flange sections (flange ≈ height): HEA is the lighter, HEB the stockier series, both better for columns and biaxial loads. If you need even more capacity at the same height, HEM is the heavy version of the same shape.

Values are entered from the governing standard’s published tables and cross-checked programmatically against its mass and section formulas before publication. Spotted an error? Write to advertising@metalabout.net — verified corrections ship within days. About