| Profile | h (mm) | b (mm) | tw (mm) | tf (mm) | G (kg/m) | A (cm²) | Ix (cm⁴) | Wx (cm³) | Iy (cm⁴) | Wy (cm³) |
|---|
| HEA 100 | 96 | 100 | 5 | 8 | 16.7 | 21.2 | 349 | 72.8 | 134 | 26.8 |
| HEA 120 | 114 | 120 | 5 | 8 | 19.9 | 25.3 | 606 | 106 | 231 | 38.5 |
| HEA 140 | 133 | 140 | 5.5 | 8.5 | 24.7 | 31.4 | 1,033 | 155 | 389 | 55.6 |
| HEA 160 | 152 | 160 | 6 | 9 | 30.4 | 38.8 | 1,673 | 220 | 616 | 76.9 |
| HEA 180 | 171 | 180 | 6 | 9.5 | 35.5 | 45.3 | 2,510 | 294 | 925 | 103 |
| HEA 200 | 190 | 200 | 6.5 | 10 | 42.3 | 53.8 | 3,692 | 389 | 1,336 | 134 |
| HEA 220 | 210 | 220 | 7 | 11 | 50.5 | 64.3 | 5,410 | 515 | 1,955 | 178 |
| HEA 240 | 230 | 240 | 7.5 | 12 | 60.3 | 76.8 | 7,763 | 675 | 2,769 | 231 |
| HEA 260 | 250 | 260 | 7.5 | 12.5 | 68.2 | 86.8 | 10,450 | 836 | 3,668 | 282 |
| HEA 280 | 270 | 280 | 8 | 13 | 76.4 | 97.3 | 13,670 | 1,013 | 4,763 | 340 |
| HEA 300 | 290 | 300 | 8.5 | 14 | 88.3 | 112 | 18,260 | 1,260 | 6,310 | 421 |
| HEA 320 | 310 | 300 | 9 | 15.5 | 97.6 | 124 | 22,930 | 1,479 | 6,985 | 466 |
| HEA 340 | 330 | 300 | 9.5 | 16.5 | 105 | 133 | 27,690 | 1,678 | 7,436 | 496 |
| HEA 360 | 350 | 300 | 10 | 17.5 | 112 | 143 | 33,090 | 1,891 | 7,887 | 526 |
| HEA 400 | 390 | 300 | 11 | 19 | 125 | 159 | 45,070 | 2,311 | 8,564 | 571 |
| HEA 450 | 440 | 300 | 11.5 | 21 | 140 | 178 | 63,720 | 2,896 | 9,465 | 631 |
| HEA 500 | 490 | 300 | 12 | 23 | 155 | 198 | 86,970 | 3,550 | 10,370 | 691 |
| HEA 550 | 540 | 300 | 12.5 | 24 | 166 | 212 | 111,900 | 4,146 | 10,820 | 721 |
| HEA 600 | 590 | 300 | 13 | 25 | 178 | 226 | 141,200 | 4,787 | 11,270 | 751 |
HEA load capacity — max. uniform load (kN/m), simply supported
Frequently Asked Questions
What is an HEA profile?
HEA is a standard European hot-rolled beam series per EN 10365 (DIN 1025-3). Sizes run from HEA 100 (16.7 kg/m) to HEA 600 (178 kg/m).
How do I read the HEA table?
h and b are the section height and flange width in mm, G is the weight per meter, A the cross-section area, Ix/Wx the moment of inertia and section modulus about the strong axis, and Iy/Wy the same about the weak axis. Click any size for the full data sheet with a worked deflection example.
How much load can an HEA beam carry?
The load capacity table above gives the maximum uniformly distributed load per span for a simply supported beam — the stricter of the L/360 deflection limit (E = 210 GPa) and an elastic bending stress of 155 MPa (≈ 0.66·fy for S235). Example: HEA 280 carries about 78.5 kN/m over a 4 m span. Preliminary sizing only — verify the final design to Eurocode 3, including shear, bearing, and lateral-torsional buckling.
What is the difference between IPE, HEA and HEB?
IPE beams are narrow and light — the default for bending about the strong axis. HEA and HEB are wide-flange sections (flange ≈ height): HEA is the lighter, HEB the stockier series, both better for columns and biaxial loads. If you need even more capacity at the same height, HEM is the heavy version of the same shape.
Values are entered from the governing standard’s published tables and cross-checked programmatically against its mass and section formulas before publication. Spotted an error? Write to advertising@metalabout.net — verified corrections ship within days. About