MetalAbout Logo

IPN Table — Dimensions, Weight & Section Properties

IPN I-beam per EN 10365 (DIN 1025-1)

Standard values for every IPN size from IPN 80 to IPN 600: dimensions, weight per meter, and the section properties needed for bending and deflection checks. Click a size for its full data sheet.

IPN — IPN 80 – IPN 600

Profileh (mm)b (mm)tw (mm)tf (mm)G (kg/m)A (cm²)Ix (cm⁴)Wx (cm³)Iy (cm⁴)Wy (cm³)
IPN 8080423.95.95.947.5877.819.56.293
IPN 100100504.56.88.3410.617134.212.24.88
IPN 120120585.17.711.114.232854.721.57.41
IPN 140140665.78.614.318.257381.935.210.7
IPN 160160746.39.517.922.893511754.714.8
IPN 180180826.910.421.927.91,45016181.319.8
IPN 200200907.511.326.233.42,14021411726
IPN 220220988.112.231.139.53,06027816233.1
IPN 2402401068.713.136.246.14,25035422141.7
IPN 2602601139.414.141.953.35,74044228851
IPN 28028011910.115.247.9617,59054236461.2
IPN 30030012510.816.254.2699,80065345172.2
IPN 32032013111.517.36177.712,51078255584.7
IPN 34034013712.218.36886.715,70092367498.4
IPN 3603601431319.576.19719,6101,090818114
IPN 38038014913.720.58410724,0101,260975131
IPN 40040015514.421.692.411829,2101,4601,160149
IPN 45045017016.224.311514745,8502,0401,730203
IPN 500500185182714117968,7402,7502,480268
IPN 550550200193016621299,1803,6103,490349
IPN 60060021521.632.4199254138,8004,6274,670434

IPN load capacity — max. uniform load (kN/m), simply supported

Profile3 m4 m5 m6 m8 m
IPN 801.290.540.280.160.07
IPN 1002.841.20.610.350.15
IPN 1205.442.31.180.680.29
IPN 1409.514.012.051.190.5
IPN 16015.56.553.351.940.82
IPN 18022.210.25.23.011.27
IPN 20029.5157.674.441.87
IPN 22038.321.4116.352.68
IPN 24048.827.415.28.813.72
IPN 26060.934.320.611.95.02
IPN 28074.74226.915.76.64
IPN 3009050.632.420.38.57
IPN 32010860.638.825.910.9
IPN 34012771.545.831.813.7
IPN 36015084.554.137.517.2
IPN 38017497.762.543.421
IPN 40020111372.450.325.6
IPN 45028115810170.339.5
IPN 50037921313694.753.3
IPN 55049728017912469.9
IPN 60063735922915989.6

Frequently Asked Questions

What is an IPN profile?

IPN is a standard European hot-rolled beam series per EN 10365 (DIN 1025-1). Sizes run from IPN 80 (5.94 kg/m) to IPN 600 (199 kg/m).

How do I read the IPN table?

h and b are the section height and flange width in mm, G is the weight per meter, A the cross-section area, Ix/Wx the moment of inertia and section modulus about the strong axis, and Iy/Wy the same about the weak axis. Click any size for the full data sheet with a worked deflection example.

How much load can an IPN beam carry?

The load capacity table above gives the maximum uniformly distributed load per span for a simply supported beam — the stricter of the L/360 deflection limit (E = 210 GPa) and an elastic bending stress of 155 MPa (≈ 0.66·fy for S235). Example: IPN 280 carries about 42 kN/m over a 4 m span. Preliminary sizing only — verify the final design to Eurocode 3, including shear, bearing, and lateral-torsional buckling.

What is the difference between IPN and IPE?

IPN is the older I-beam series with tapered inner flange faces (14% slope) per DIN 1025-1; IPE has parallel flanges and a more efficient cross-section. IPE is the default for new designs, but IPN remains common in renovations, machine building, and crane rails — and its narrower flanges can be an advantage in tight details.

Values are entered from the governing standard’s published tables and cross-checked programmatically against its mass and section formulas before publication. Spotted an error? Write to advertising@metalabout.net — verified corrections ship within days. About